Indoor and Built Environment

 

Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Register here to gain access to SAGE's 500+ Journals Online

Sign In to gain access to subscriptions and/or personal tools.
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via ISI Web of Science (1)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Sun, W.
Right arrow Articles by Ji, J.
Right arrow Search for Related Content
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
Indoor and Built Environment, Vol. 16, No. 6, 493-504 (2007)
DOI: 10.1177/1420326X07084290

Transport of Droplets Expelled by Coughing in Ventilated Rooms

Wei Sun

Department of Thermal Science and Energy Engineering, University of Science and Technology of China, Hefei, Anhui 230027, P.R. China

Jie Ji

Department of Thermal Science and Energy Engineering, University of Science and Technology of China, Hefei, Anhui 230027, P.R. China, jijie{at}ustc.edu.cn

This study aims to understand the transport and dispersal of droplets produced by coughing in a ventilated room. Experiments were conducted to measure the initial velocity and the duration of a coughing burst. Computational fluid dynamics with a Eulerian—Lagrangian model was used to investigate the transport characteristics of evaporating droplets expelled into the ventilated room. The simulation results indicate that if expelled horizontally the droplets finally settle if their initial size is >100 µm, while if expelled upwards the droplets only settle if their initial size is ≥300 µm. Different ventilation set-ups vary in their ability to remove droplets produced by coughing. The mixing ventilation system has an almost equal efficiency for removing small passive droplets and the nuclei of droplets whose original size was 100 and 80 µm, respectively. For displacement ventilation, although it has high efficiency in removing small passive droplets, it has difficulty in removing the nuclei of large droplets. In the displacement system, small droplets show a two-zonal distribution in the room, but the nuclei of large droplets are subjected to gravitational force and tend to settle in the lower part of the room.

Key Words: Coughing • Evaporating droplets • CFD • Ventilation


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?