Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Sign In to gain access to subscriptions and/or personal tools.
Indoor and Built Environment
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Web of Science (3)
Right arrow Citing Articles via Google Scholar
Right arrow Citing Articles via Scopus
Google Scholar
Right arrow Articles by Wong, L.T.
Right arrow Articles by Hui, P.S.
Right arrow Search for Related Content
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati   Add to Twitter  
What's this?

Screening for Indoor air Quality of Air-Conditioned Offices

L.T. Wong

Department of Building Services Engineering, The Hong Kong Polytechnic University, Hung Hom Kowloon, Hong Kong, China, beltw{at}polyu.edu.hk

K.W. Mui

Department of Building Services Engineering, The Hong Kong Polytechnic University, Hung Hom Kowloon, Hong Kong, China

P.S. Hui

Department of Building Services Engineering, The Hong Kong Polytechnic University, Hung Hom Kowloon, Hong Kong, China

It would be costly to sample all toxic air pollutants to which an entire community is exposed. In Hong Kong, a voluntary Indoor Air Quality (IAQ) certification scheme for IAQ assessment in workplaces proposes the measurement of the levels of 12 parameters: carbon dioxide, carbon monoxide, respirable suspended particulates, nitrogen dioxide, ozone, formaldehyde, total volatile organic compounds, radon, airborne bacteria count, temperature, relative humidity and air velocity. This study investigates the feasibility of a screening process for presumptive detection of unrecognised IAQ problems in an indoor environment. From the full IAQ assessment results of 422 air-conditioned offices in Hong Kong, three of nine listed common air pollutants are selected as ``representative'' pollutants for an overall ``satisfactory IAQ''. In particular, an ``IAQ index'' using the average fractional dose corresponding to given exposure limits of the representative pollutants as a simple screening test for asymptomatic IAQ problems in air-conditioned offices is proposed. The index was evaluated in terms of test sensitivity, specificity and predictive value. Such a screening test would be a useful tool for policymakers, building owners and professionals to identify offices with probable IAQ problems. Making better decisions regarding resources for an IAQ surveillance programme could help to ensure a healthy and safe workplace.

Key Words: Screening test • Indoor air pollutants • IAQ index • Air-conditioned offices

Indoor and Built Environment, Vol. 16, No. 5, 438-443 (2007)
DOI: 10.1177/1420326X07082159


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter    What's this?


This article has been cited by other articles:


Home page
BUILDING SERV ENG RES TECHNOLHome page
L. Wong, K. Mui, and P. Hui
Evaluation on screening strategies for indoor air quality assessments in air-conditioned offices
Building Service Engineering, August 1, 2009; 30(3): 203 - 212.
[Abstract] [PDF]